travels depends on the temperature difference. One factor here is time of the year. Due to lack of information, this cannot be calculated.

Conclusions

Given the limited information available, the following figures can be calculated.

The temperature rise for an empty room, but with robots at work inside is between 1,4 and 6,6 K/hour (1 K=1 degree C). Obviously, the robots will not be working inside an empty room:

With inside equipment based on an educated guess, the temperature rise will be between 0,02 and 0,1 K/hour.

If more information could be made available, more accurate calculations could be performed.

166

FFI-RAPPORT 16/00707